0001 What:           /sys/bus/iio/devices/device[n]/in_illuminance_calibrate
0002 KernelVersion:  2.6.37
0003 Contact:        linux-iio@vger.kernel.org
0004 Description:
0005                 This property causes an internal calibration of the als gain trim
0006                 value which is later used in calculating illuminance in lux.
0007 
0008 What:           /sys/bus/iio/devices/device[n]/in_illuminance_lux_table
0009 KernelVersion:  2.6.37
0010 Contact:        linux-iio@vger.kernel.org
0011 Description:
0012                 This property gets/sets the table of coefficients
0013                 used in calculating illuminance in lux.
0014 
0015 What:           /sys/bus/iio/devices/device[n]/in_illuminance_input_target
0016 KernelVersion:  2.6.37
0017 Contact:        linux-iio@vger.kernel.org
0018 Description:
0019                 This property is the known externally illuminance (in lux).
0020                 It is used in the process of calibrating the device accuracy.