Back to home page

OSCL-LXR

 
 

    


0001 What:           /sys/bus/iio/devices/iio:deviceX/in_voltageY_sensing_mode
0002 Date:           August 2015
0003 KernelVersion:  4.2.0
0004 Contact:        source@cogentembedded.com
0005 Description:
0006                 Program sensor type for threshold detector inputs.
0007                 Could be either "GND-Open" or "Supply-Open" mode. Y is a
0008                 threshold detector input channel. Channels 0..7, 8..15, 16..23
0009                 and 24..31 has common sensor types.
0010 
0011 What:           /sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_falling_value
0012 Date:           August 2015
0013 KernelVersion:  4.2.0
0014 Contact:        source@cogentembedded.com
0015 Description:
0016                 Channel Y low voltage threshold. If sensor input voltage goes lower then
0017                 this value then the threshold falling event is pushed.
0018                 Depending on in_voltageY_sensing_mode the low voltage threshold
0019                 is separately set for "GND-Open" and "Supply-Open" modes.
0020                 Channels 0..31 have common low threshold values, but could have different
0021                 sensing_modes.
0022 
0023                 The low voltage threshold range is between 2..21V.
0024                 Hysteresis between low and high thresholds can not be lower then 2 and
0025                 can not be odd.
0026 
0027                 If falling threshold results hysteresis to odd value then rising
0028                 threshold is automatically subtracted by one.
0029 
0030 What:           /sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_rising_value
0031 Date:           August 2015
0032 KernelVersion:  4.2.0
0033 Contact:        source@cogentembedded.com
0034 Description:
0035                 Channel Y high voltage threshold. If sensor input voltage goes higher then
0036                 this value then the threshold rising event is pushed.
0037                 Depending on in_voltageY_sensing_mode the high voltage threshold
0038                 is separately set for "GND-Open" and "Supply-Open" modes.
0039 
0040                 Channels 0..31 have common high threshold values, but could have different
0041                 sensing_modes.
0042 
0043                 The high voltage threshold range is between 3..22V.
0044                 Hysteresis between low and high thresholds can not be lower then 2 and
0045                 can not be odd.
0046 
0047                 If rising threshold results hysteresis to odd value then falling
0048                 threshold is automatically appended by one.